THE ELIMINATOR CG
Room Temperature Purifier for Inert Gases
APPLICATIONS
-
Zero-Hydrocarbon UHP Inert Gas Purge
-
APIMS Zero and Calibration
-
Semiconductor Process Equipment
-
Gas Cylinder Cabinets
-
Gas Analyzer Carts
-
Analytical Industry
-
Research and Development
FEATURES
-
Outlet purity guarantee to < 0.5 ppb1
-
Removes all hydrocarbons, including CH4
-
No heaters or power required
-
Room-temperature operation
-
316L SS (<10 Ra EP) vessel
-
Factory regenerable for up 10 year life
-
Field regenerable for up to 10 year life
-
Improved process equipment perfomance
-
Optional built-in 0.003 µm filter (PF type)
-
High Flow - up to 2500 slpm
-
Lowest cost (initial and operating)
NuPure's Eliminator® CG Gas Purifier is designed to purify Inert Gases (Nitrogen or Noble Gases) to state-of-the-art purity, using a patented design and process. It removes all hydrocarbons (including methane), and all other gaseous impurities found in Inert gases, to PPT levels using room temperature operation. The Eliminator® CG is ideal for critical process and purging applications.
The NuPure® Eliminator® CG contains a new patented combination of catalyst and metal getter. It contains no hydrocarbon or sulfur compounds. The Eliminator® CG Purifier incorporates a new unique internal filter design combined with a short purifier geometry, allowing a very high flow combined with a very low pressure drop.
The Eliminator® CG gas purifiers come in standard size ranges from 0 to 2500 slpm. The use of optional factory-installed inlet isolation valve (shown in photo) is recommended for elimination of possible operator error during installation. Optional high Cv valves are available to ensure a low system pressure drop.
IMPURITIES REMOVED
1 - Based on a VLSI Grade Liquid Gas source. Nitrogen not removed from noble gases.. Removal of nitrogen can be accomplished using heated getter purifiers. See brochures for NuPure® PF Series™ and Omni™ Series Gas Purifiers.
Dimensional and Performance Specifications
1 - Sub-micron filtration only with PF version.
2 - For model 1000 dimension “A” have changed from 12.1 inches to 12.9 inches, dimension “B” has changed from 10.3 inches to 11.1 inches.
3 - For models 5000 and larger - the printed dimensions are subject to future change. Please check with factory prior ordering.
4 - VCR-compatible fittings standard. VCR is Registered Trademark of Cajon Corp. Special fittings on request.